H. Mizumoto, M. Yabuya, T. Shimizu, and K. Y. , An angstrom-positioning system using a twist-roller friction drive, Precision Engineering, vol.17, issue.1, pp.57-62, 1995.
DOI : 10.1016/0141-6359(94)00010-W

J. Hwang, C. Park, C. Lee, and K. , Estimation and correction method for the two-dimensional position errors of a planar XY stage based on motion error measurements, International Journal of Machine Tools & manufacture, pp.1-12, 2005.

W. Gao, Y. Arai, A. Shibuya, S. Kiyono, and C. Park, Measurement of multi-degree-of-freedom error motions of a precision linear air-bearing stage, Prec. Eng. 30 96-103 [5] The international technology Roadmap for semiconductors, 2005.

C. Lee and K. , An ultraprecision stage for alignment of wafers in advanced microlithography, Precision Engineering, vol.21, issue.2-3, pp.113-122, 1997.
DOI : 10.1016/S0141-6359(97)00080-9

F. Meli and R. Thalmann, Long-range AFM profiler used for accurate pitch measurements, Measurement Science and Technology, vol.9, issue.7, pp.1087-1092, 1998.
DOI : 10.1088/0957-0233/9/7/014

C. Chu and F. , A novel long-travel piezoelectric-driven linear nanopositioning stage, Precision Engineering, vol.30, issue.1, pp.85-95, 2006.
DOI : 10.1016/j.precisioneng.2005.05.002

H. Liu, B. Lu, Y. Ding, Y. Tang, and D. Li, A motor-piezo actuator for nano-scale positioning based on dual servo loop and nonlinearity compensation, Journal of Micromechanics and Microengineering, vol.13, issue.2, pp.295-299, 2003.
DOI : 10.1088/0960-1317/13/2/318

J. Fu, R. Young, and T. Vorburger, Long???range scanning for scanning tunneling microscopy, Review of Scientific Instruments, vol.63, issue.4, pp.2200-2205, 1992.
DOI : 10.1063/1.1143139

H. Yeh, W. Ni, and S. Pan, Digital closed-loop nanopositioning using rectilinear flexure stage and laser interferometry, Digital closed-loop nanopositioning using rectilinear flexure stage and laser interferometry, pp.559-566, 2005.
DOI : 10.1016/j.conengprac.2004.04.019

M. Holmes, R. Hocken, and D. Trumper, The long-range scanning stage: a novel platform for scanned-probe microscopy, Precision Engineering, vol.24, issue.3, pp.191-209, 2000.
DOI : 10.1016/S0141-6359(99)00044-6

J. Haycocks and J. K. , Traceable calibration of transfer standards for scanning probe microscopy, Precision Engineering, vol.29, issue.2, pp.168-175, 2005.
DOI : 10.1016/j.precisioneng.2004.06.002

I. Misumi, S. Gonda, T. Kurosawa, Y. Azuma, T. Fujimoto et al., Reliability of parameters of associated base straight line in step height samples: Uncertainty evaluation in step height measurements using nanometrological AFM, Precision Engineering, vol.30, issue.1, pp.13-22, 2006.
DOI : 10.1016/j.precisioneng.2005.03.002

S. Topçu, L. Chassagne, D. Haddad, Y. Alayli, and P. Juncar, Heterodyne interferometric technique for displacement control at sub-nanometric scale, Rev. Sci. Instrum, vol.74, pp.4875-4880, 2003.

F. Demarest, High-resolution, high-speed, low data age uncertainty, heterodyne displacement measuring interferometer electronics, Measurement Science and Technology, vol.9, issue.7, pp.1024-1030, 1998.
DOI : 10.1088/0957-0233/9/7/003

L. Chassagne, S. Topcu, Y. Alayli, and P. Juncar, Highly accurate positioning control method for piezoelectric actuators based on phase-shifting optoelectronics, Measurement Science and Technology, vol.16, issue.9, pp.1771-1777, 2005.
DOI : 10.1088/0957-0233/16/9/008

K. P. Birch and M. Downs, An Updated Edl??n Equation for the Refractive Index of Air, Metrologia, vol.30, issue.3, p.155, 1993.
DOI : 10.1088/0026-1394/30/3/004

C. Sutton, Non-linearity in length measurement using heterodyne laser Michelson interferometry, Journal of Physics E: Scientific Instruments, vol.20, issue.10, pp.1290-1292, 1987.
DOI : 10.1088/0022-3735/20/10/034

C. Wu and C. Su, Nonlinearity in measurements of length by optical interferometry, Measurement Science and Technology, vol.7, issue.1, pp.62-68, 1996.
DOI : 10.1088/0957-0233/7/1/009

A. E. Rosenbluth and N. Bobroff, Optical sources of non-linearity in heterodyne interferometers, Precision Engineering, vol.12, issue.1, pp.7-11, 1990.
DOI : 10.1016/0141-6359(90)90003-H

S. Topçu, L. Chassagne, Y. Alayli, and P. Juncar, Improving the accuracy of homodyne Michelson interferometers using polarisation state measurement techniques, Optics Communications, vol.247, issue.1-3, pp.133-139, 2005.
DOI : 10.1016/j.optcom.2004.11.040

S. Topçu, L. Chassagne, D. Haddad, Y. Alayli, and P. Juncar, High accuracy velocity control method for the french moving-coil watt balance, Review of Scientific Instruments, vol.75, issue.11, pp.4824-4827, 2004.
DOI : 10.1063/1.1809302